BHWGC - SPADNS REAGENT FOR FLUORIDE
- MSDS: BHWGC
- Manufacturer: HACH CO
- Product Name: SPADNS REAGENT FOR FLUORIDE
- National Stock Number: 6810-01-105-1428
Product Identification
Product ID:SPADNS REAGENT FOR FLUORIDE
MSDS Date:07/10/1987
FSC:6810
NIIN:01-105-1428
MSDS Number: BHWGC
Responsible Party
US
Emergency Phone: 515-232-2533
Info Phone: 515-232-2533
Cage: 4T252
Contractor
Telephone: 800-227-4224
Cage: 4T252
Ingredients
SODIUM ARSENITE (SARA III)
CAS: 7784-46-5
RTECS: CG3675000
Fraction By Weight: <0.5%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.2 MG AS/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
HYDROGEN CHLORIDE (HYDROCHLORIC ACID) (SARA III)
CAS: 7647-01-0
RTECS: MW4025000
Fraction By Weight: <40%
OSHA PEL C 5 PPM
ACGIH TLV: C 5 PPM; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
OTHER COMPONENTS,EACH <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
DEMINERALIZED WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: TO 100%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:LD50 RAT ORAL 540 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:CORROSIVE TO EYES,SKIN AND RESPIRATORY
TRACT.
Explanation of Carcinogenicity:ARSENIC ACID ARSENIC COMPOUND:SUFFICIENT
HUMAN/LIMITED ANIMAL (IARC 1987).KNOWN HUMAN CARCINOGEN (NTP 1985).
Effects of Overexposure:EYES:CORROSIVE.CAUSES
BURNS.SKIN:CORROSIVE,CAUSES BURNS.INGESTION:CAUSES
BURNS,CORROSIVE.SEDATION,TWITCHING.INHALATION:CORROSIVE.CAUSES
BURNS.
Medical Cond Aggravated by Exposure:PERSONS WITH IMPAIRED PULMONARY
FUNCTION MAY BE AT INCREASED RISK FROM FUMES.
First Aid
First Aid:EYES:IMMEDIATELY FLUSH EYES WITH WATER FOR 15 MINUTES.CALL
PHYSICIAN.SKIN:IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.REMOVE
CONTAMINATED CLOTHING.CALL PHYSICIAN.INGESTION:DO NOT INDUCE
VOMITING.IF CO NSCIOUS GIVE WATER.GIVE 1 OUNCE OF MILKOF MAGNESIA
IN 1 OUNCE OF WATER OR THREE EGG WHITES.CALL
PHYSICIAN.INHALATION:REMOVE TO FRESH AIR.GIVE ARTIFICIAL
RESPIRATION IF NECESSARY.CALL PHYSICIAN.
Fire Fighting
Extinguishing Media:DRY CHEMICAL.
Fire Fighting Procedures:N/K
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES.HAZARDOUS
DECOMPOSITION PRODUCTS ARE:TOXIC FUMES OF ARSENIC AND CHLORIDES.
Accidental Release
Spill Release Procedures:COVER CONTAMINATED SURFACE WITH SODIUM
BICARBONATE OR SODA ASH-SLAKED LIME MIXTURE (50-50).MIX AND ADD
WATER IF NECESSARY TO FORM SLURRY.SCOOP UP SLURRY AND WASH DOWN THE
DRAIN WITH EXCESS WATER.WASH THE SITE WITH SODA ASH SOLUTION.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:WASH THOROUGHLY AFTER HANDLING.AVOID
CONTACT WITH EYES,SKIN AND CLOTHING.STORE TIGHTLY CLOSED.
Other Precautions:N/K
Exposure Controls
Respiratory Protection:N/K
Ventilation:ADEQUATE VENTILATION.
Protective Gloves:DISPOSABLE
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:LAB COAT
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
CORROSIVITY:CORROSIVE TO ALUMINUM,STEEL 0.207 IN/YR.SOLUBILITY IN
ACID:MISCIBLE.
Chemical Properties
Boiling Pt:B.P. Text:221F,105C
Decomp Temp:Decomp Text:N/K
Spec Gravity:1.015 (WATER=1)
pH:<0.5
Evaporation Rate & Reference:0.64
Solubility in Water:MISCIBLE
Appearance and Odor:DARK RED SOLUTION,ODORLESS.
Corrosion Rate:SEE SUPP
Stability
Stability Indicator/Materials to Avoid:YES
N/K
Stability Condition to Avoid:STRONG OXIDIZERS.
Hazardous Decomposition Products:TOXIC FUMES OF ARESENIC AND CHLORIDES.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS.COORDINATION WITH SUPPORTING
INSTALLATION AND/OR MACOM ENVIRONMENTAL COORDINATION PRIOR TO
DISPOSAL IS RECOMMENDED TO DETERMINE APPROPRIATE DISPOSAL METHODS
.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.